CLUMP Tank Washing Nozzles

Clog-Resistant Stationary Tank Cleaning Devices
Detail Tank Cleaning Spray Pattern Icon

DESIGN FEATURES

Spray nozzle heads for industrial tank cleaning, drum, and tote washing

Six clog-resistant MaxiPass® full cone nozzles arranged in a cluster to project spray in all directions

Can be supplied with various BETE nozzles for any desired application

Spherical omnidirectional coverage


HOW SPRAY PATTERN IS ACHIEVED

A manifold distributes water to several standard full cone nozzles with orientations positioned to achieve a full omnidirectional spray coverage

Available Spray Angle
360°
Flow Rate Range
7.38 to 124 gpm
Available Connection Types
  • Pipe: 3/4, 1
  • Connection Methods: Thread (NPT, BSP, Female)
Materials
Brass, 316, A494 CW2M (cast Nickel Alloy C-276)
Flow Rates, Spray Angles, Connections
Tank Cleaning
Select a nozzle number below for performance graph, drawings, and to request a quote.
Flow rate (gpm/lpm) is calculated at differential pressure (psi/bar).
Nozzle Number
Connection Sizes
Spray Angles
Flow Rate (gpm) @ Differential Pressure (psi) (Density: 1 SG)
10 psi
20 psi
30 psi
40 psi
50 psi
60 psi
Pipe: 3/4
360°
7.38
10.2
12.4
14.2
15.7
17.1
Pipe: 3/4
360°
11.7
16.2
19.6
22.4
24.9
27.1
Pipe: 3/4, 1
360°
16.9
23.4
28.3
32.4
36.0
39.2
Pipe: 1
360°
26.9
37.2
45.0
51.5
57.2
62.3
Pipe: 1
360°
30.4
42.1
50.9
58.3
64.8
70.6