DESIGN FEATURES
Effective, economical way to circulate liquids in closed or open tanks
No moving parts, clog-resistant
Requires minimal maintenance
Nozzle operation creates a multiplying effect on fluid flow; the volume of discharge liquid will be 3-5 times greater than the motive liquid pumped
Cone-shaped plume
HOW SPRAY PATTERN IS ACHIEVED
In eductor nozzles, the initial fluid pumped into the system is combined with the tank contents within the nozzle before being sprayed back into the tank.
Available Spray Angle
0°
Flow Rate Range
6.96 to 3180 gpm
Available Connection Types
- Pipe: 3/8, 1/2, 3/4, 1, 1 1/2, 2, 3, 4, 6, 8
- Connection Methods: Thread (NPT, BSP, Male, Female), Flange (150#)
Materials
Glass-filled Polypropylene, Brass, Carbon Steel, 316
Flow Rates, Spray Angles, Connections
Submerged Jet
Select a nozzle number below for performance graph, drawings, and to request a quote.
Flow rate (gpm/lpm) is calculated at differential pressure (psi/bar).
Nozzle Number
Connection Sizes
Spray Angles
Flow Rate (gpm) @ Differential Pressure (psi) (Density: 1 SG)
10 psi
20 psi
30 psi
40 psi
80 psi
100 psi
6.96
9.84
12.0
13.9
19.7
22.0
7.27
10.3
12.6
14.5
-
-
11.1
15.7
19.2
22.1
31.3
35.0
12.0
17.0
20.8
24.0
-
-
13.6
19.2
23.6
27.2
-
-
14.9
21.0
25.7
29.7
42.0
47.0
23.1
32.6
40.0
46.2
65.3
73.0
24.0
34.0
41.6
48.1
-
-
31.9
45.2
55.3
63.9
90.3
101
34.2
48.3
59.2
68.3
-
-
62.0
87.7
107
124
175
196
150
212
260
300
424
474
251
355
435
502
710
794
601
850
1040
1200
1700
1900
1010
1420
1740
2010
2840
3180